100 percent water soluble and 100 percent Volatile corrosion inhibitor for Low Medium High Pressure Boiler Water System.
Corrosion Inhibitor for Boiler Neutralizer Concentrated liquid neutralising agent for corrosion control in condensate and feed water systems, contain blends of low, medium and high volatility amines that provide great protection and neutralization of acidic gases, such as CO2 throughout a condensate system. Protects boiler surfaces by forming an iron tannate film.
A liquid neutralizing amine used to control corrosion and pH in steam and condensate systems.
Hydrazine Based oxygen scavenger and Corrosion inhibitor controls ferrous and non-ferrous corrosion in feedwater, boilers, steam, and condensate lines.
Corrosion Inhibitor for Boiler Neutralizer is a blend of volatile liquid / steam distributions ratios that neutralise the acid contaminants in condensate and feed water thus providing protection against acid corrosion in the complete system.The most common cause of acid corrosion in condensate and feed water systems is dissolved carbon dioxide. Condensate control neutralises this acid and maintains the condensate and feed water in an alkaline condition
Used in medium and high-pressure boilers including ultra high-pressure boilers.
Fields Of Application:-
Corrosion Inhibitor for Boiler Neutralizer is an effective neutralizing type corrosion inhibitor & oxygen scavanger for steam condensation system. And can also be used to protect Boilers /Metals surfaces form corrosion.It removes oxygen efficiently in open feed systems and gives effective corrosion inhibition of boiler/exhaust gas economizer system surfaces . Its Chemical reaction by converting Fe2O3 (rust) to organic iron compound protect further IRON rust reaction .
Operating Process:-
RXSOL-CC72 neutralizes the acid components of feed water.The proportion of Corrosion Inhibitor for Boiler Neutralizer depends upon the Carbon dioxide content of the condensate. Basically Corrosion Inhibitor for Boiler Neutralizer neutralizes the acid contents & maintains the condensate and feed water in the alkaline condition. It also protects copper based metals.
AMERZAMINE Corrosion Inhibitor for Boiler Neutralizer condensate is tested for PH to determine the dosage level. The PH limits are 8.3 - 9.0 . For an average system e. g. 10-M3, the dosage is approximately 0.15 ltr / day .
The necessary amount of Corrosion Inhibitor for Boiler Neutralizer is required or injected as frequently as to maintain the pH of the condensate at the main condensate pump outlet between 8.6-9.5 . The amines pass over with the steam and have the dual function of elevating the pH of the steam/condensate and putting a protective micro film on the system pipe work. Acidic condensate is the result of carbonic acid (H2CO3) being formed as CO2 is released in the steam.Condensate prevents corrosion by carbonic acid on live systems. Its filming properties also reduce corrosion on shut down lines, when moisture and oxygen are present.
Why AMERZAMINE corrosion inhibitor is important for Boiler System?
AMERZAMINE corrosion inhibitor form protective oxide films and passivates metal surfaces.
AMERZAMINE manufacturer and supplier in India UAE Oman. AMERZAMINE Boiler Condensate Corrosion Control chemical manufacturer supplier in India UAE Oman.
| Other Brand |
RXSOL PRODUCT NAME
|
RXSOL PRODUCT CODE
|
Remarks
|
| AMERZINE |
AMERZAMINE
|
RXSOL-14-5005-554
|
CHEMICALS REQUIRED FOR BOILER WATER TREATMENTS. 100 percent water soluble and 100 percent Volatile corrosion inhibitor for Low Medium High Pressure Boiler Water System. |
| AGK 100 |
One Shot Universal Liquitreat 100
|
RXSOL-50-5001-025
|
CHEMICALS REQUIRED FOR BOILER WATER TREATMENTS. A one-step and one SHOT treatment to control the formation of rust and scale in boilers. Contains alkaline compounds, scale and corrosion inhibitors, oxygen scavengers and sludge conditioners |
| AMEROYAL |
AMEROL Evaporator Treatment
|
RXSOL-60-6001-025
|
CHEMICALS REQUIRED FOR FWG TREATMENTS. AMEROL Evaporator Treatment: Advanced Scale & Foam Control for Evaporators |
| DESCALE IT |
Descaling Liquid
|
RXSOL-11-1008-025
|
CHEMICALS REQUIRED FOR CLEANING THE FWG PLATES. Hardness Scale Dissolving Chemicals resulting parts from OVER HEATING. |
| ENVIROCARE VTC 4000 |
BTC Zyme
|
RXSOL-15-1496-025
|
CHEMICALS REQUIRED FOR TOILETS CLEANING AS CANOT USE OTHER CHEMICALS. Unique biological active liquid formulation containing specialized bacterial strains, biodegradable low foaming chemical cleaners and anti foam agents. |
| ENVIROMATE 2000 |
Enviro 2000 Soft
|
RXSOL-20-3022-025
|
CHEMICALS REQUIRED FOR CLEANING. Advance general cleaner Degreaser suitable for PRESSURE washing equipment, Also have pleasant odour and safe to the persons handling it . Can be used as a multipurpose cleaner for tank or general cleaning and all types of cleaning and degreasing operations. |
| LIQUIDEWT |
Engine Water Treatment DEWT
|
RXSOL-40-4010-025
|
CHEMICALS REQUIRED FOR HT and LT COOLING WATER SYSTEM. Multi-functional corrosion inhibitor for protecting recirculating cooling and heating water systems. RXSOL LIQUID EWT treatment is an excellent treatment for diesel engine primary and secondary cooling water. It is also ideally suited for use in chilled water systems. |
| LT SOOT RELEASE |
50
|
KG
|
CHEMICALS REQUIRED FOR ME EXHAUST GAS BOILER SOOT FLUSHING.
|
Basic Boiler System Schematic
Below is a summary of problems associated with the common impurities in water and solutions to each problem.
List Of Problems Caused By Impurities In Water
|
Impurity (Chemical Formula) |
Problems |
Common Chemical Treatment Methods |
|
Alkalinity (HCO3-, CO32- and CaCO3) |
Carryover of feedwater into steam, produce CO2 in steam leading to formation of carbonic acid (acid attack) |
Neutralizing amines, filming amines, combination of both, and lime-soda. |
|
Hardness (calcium and magnesium salts, CaCO3) |
Primary source of scale in heat exchange equipment |
Lime softening, phosphate, chelates and polymers |
|
Iron (Fe3+ and Fe2+) |
Causes boiler and water line deposits |
Phosphate, chelates and polymers |
|
Oxygen (O2) |
Corrosion of water lines, boiler, return lines, heat exchanger equipments, etc. (oxygen attack) |
Oxygen scavengers, filming amines and deaeration |
|
pH |
Corrosion occurs when pH drops below 8.5 |
pH can be lowered by addition of acids and increased by addition of alkalies |
|
Hydrogen Sulfide (H2S) |
Corrosion |
Chlorination |
|
Silica (SiO2) |
Scale in boilers and cooling water systems |
Lime softening |
Amerzine 25 Ltr