MICRO BIOCIDE Cooling Water

Product code RXSOL-40-4009-025

Effective controller of MICRO BIOCIDE and BACTERIA from condensor WATER system. being effective against most kinds of bacteriaa, algae and fungi. It is a particularly useful product for air-wash systems and is compatible with all commonly used antifo

Description

Effective controller of MICRO BIOCIDE and BACTERIA from condensor WATER system. being effective against most kinds of bacteriaa, algae and fungi. It is a particularly useful product for air-wash systems and is compatible with all commonly used antifoulants and corrosion inhibitors . For the control of microbial biofilms, bacteria, algae, and fungi, add MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 to industrial recirculating water cooling towers, industrial recirculating closed loop water cooling systems, brewery pasteurizer and can warmer systems.

Application
Application

Microbiocide based on Organo sulphur compound, for use in open recircurculating systems.

* Highly effective
* Broad spectrum activity
* Economical and easy to use
* Compatible with other treatments.

Precautions
Precautions
Where MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 can be used?

For the control of microbial biofilms, bacteria, algae, and fungi, add MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 to industrial recirculating water cooling towers, industrial recirculating closed loop water cooling systems, brewery pasteurizer and can warmer systems. Add MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 at some point in the system to ensure uniform mixing.

Dose Ratio of 
MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 
NOTE: Badly fouled systems should be cleaned before treatment.
  INITIAL DOSE: if the system is initiating fouling then use 200 ml - 3 ltr of  MICRO BIOCIDE Cooling Water RXSOL-40-4009-025  for per 3000 to 5000 Ltr of water in the system.) Dose can be increased till optimum results.   WEEKLY CONTROL DOSE: When microbial control is evident, add 100 to 500 ml per MICRO BIOCIDE Cooling Water RXSOL-40-4009-025  for per 3000 to 5000 Ltr of water in the system   AIR WASHER SYSTEMS : Add to the air washer sump or chill water sump to insure uniform mixing, 200 ml  - 3 Ltr of MICRO BIOCIDE Cooling Water RXSOL-40-4009-025  for per 3000 to 5000 Ltr of water in the system, DOSE ration directly proportional of  contamination to control microbial biofilms, bacteria, fungi, and algae which cause fouling in industrial air washer systems.  

Dose Ratio of MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 for CONTINUOUS FEED METHOD  
Maintain this treatment level by adding a continuous feed of 100 ml to 1000 ml of MICRO BIOCIDE Cooling Water RXSOL-40-4009-025  per 1000 gallon of makeup water).

NOTE : Badly fouled systems must be cleaned before initial treatment.       Dose Ratio of MICRO BIOCIDE Cooling Water RXSOL-40-4009-025 for INDUSTRIAL WASTEWATER TREATMENT SYSTEMS AND SEWAGE SYSTEMS
INITIAL DOSE for Noticeably Fouled Condition: 500 ml - 4000 ml of MICRO BIOCIDE Cooling Water RXSOL-40-4009-025  per 3000 Ltr of water in the system. Repeat until control is achieved. Badly fouled systems should be cleaned before treatment is begun.
SUBSEQUENT DOSE: When microbial control is evident, add 100 ml  - 100 ml MICRO BIOCIDE Cooling Water RXSOL-40-4009-025  per 3000 Ltr of water in the system.