Boiler Chemicals-42




Alkalinity Control

Product Code ::RXSOL-50-5002-025
Product Short Description: Alkalinity Builder Very usefull Concentrated Alkaline Liquid For Maintaining Ph which protects corrosion, scalling by controlling Calcium scale in water system.
Remarks:

The presence of alkalinity in a water sample may be due to many different substances.  However, for the sake of simplicity, the presence of bicarbonate, carbonate, and hydroxide ions is commonly considered as alkalinity.  The points of change in colour of phenolphthalein and methyl orange indicators, which occur at pH 8.3 and pH 4.3 provide standard reference points which are almost universally used to express alkalinity.

Very high alkalinity values can be undesirable in an industrial water supply.  For example, the presence of a high methyl orange alkalinity should be avoided in boiler feed water because of the resultant carbon dioxide content of the steam.  Carbon dioxide usually is responsible for the corrosion of steam and return lines.  High boiler water alkalinities are also undesirable because the presence of high hydroxide ion concentration is the primary cause of caustic metal embrittlement. A very high boiler alkalinity can also lead to an undesirable carryover condition.  On the other hand, the alkalinity of boiler water must be sufficiently high to protect the boiler metal against acidic corrosion and to ensure precipitation of scale-forming salts.  Usual treatment approaches include setting both a minimum alkalinity level and an operating range.
 

Hydroxide alkalinity may be determined by adding barium chloride prior to titration to precipitate the carbonate ion from solution, allowing direct titration of the hydroxide alkalinity.  Measurement of hydroxide alkalinity is also used to control lime soda softeners.
 

In cooling water systems, alkalinity is of major importance since the total alkalinity of a water is one factor that must be considered when predicting the tendency for the water to precipitate calcium carbonate scale.  Depending on the choice of chemical treatments to protect against corrosion and scale formation, the operating alkalinity and pH ranges are chosen to balance these two features.

 

Alkalinity Titrimetric Method (0-200 ppm) 

Principle Theory

This test is based on the determination of alkalinity by titration with standard acid to the phenolphthalein color change (or to a pH of 8.3) and to the methyl orange color change (or a pH of 4.3).  For determination of hydroxide alkalinity only, barium chloride is added prior to titration to precipitate the carbonate ions.  Titration is then taken only to the phenolphthalein end point.  A pH meter may be used instead of the indicators to determine the end points of the titration.

Other Equivalent Brand:

GREEN AC, Alka Active Liquid, GC Concentrated Alkaline Liq, Alka Treat, ACT 100 NORCHEM, Alkaline Treatment Liquid 9-512, Eazy Neutralise, ALKATREAT, Nalco 77224, PH Neutraliser, Maxtreat-3004, Nalco 77222, Chem 3004- Alkali, DREW GC, INDION 1508, Chemical For Ph Alkalinity Indion-1508 Ion Exchange, Max Clean-05 Thermax, Nalco8940 Gr100, Alkanity Control 25 Ltr

Images: Alt

Keyword:

Testing control procedure

  1. Test water sample from the water boiler as described in the direction of the  Alkalinity Test Kit ( p & m Total ) http://www.rxmarine.com/Alkalinity-test-kit
  2. Determine the present alkalinity value expressed as ppm CaCO3 .
  3. Desired level of 100-150 ppm as CaCO3.
  4. A control test for the alkalinity  of the water should be conducted after 3- 6 hours from the application.

CHARACTERISTICS

  • Alkalinity balace mechnism to control corrosion.
  • It converts calcium hardness into soft, non-adherent sludge that is easily removed by blowdown. Treated as good salt-scale controler product.
  • Compatible with other BOILER chemicals
  • Tested with long and continious running plant for more then 20 Years and easy to apply and use.
  • Avoid contact with any acidic / oily - FAT materials.

packaing_size:

Boiler Water Treatment Chemicals Alkalinity Control manufacturer and supplier in India UAE Oman, Alkalinity Control is most valuable Boiler water Treatment chemicals to converts calcium hardness into soft, non-adherent sludge that is easily removed by blowdown. Alkalinity controller boiler chemical manufacturer and supplier in Mumbai, Chennai, Kolkata, Visakhapatnam, Surat, Gandhidham, Chennai Ennore, Paradip, Nashisk, Pune, Varanashi, Patna, Tata, Ranchi, Fujairah, Sharjah, Ajman, Abudhabi, Dubai, UAE Gulf, Barka, Ruwi Ghala, Muscat Oman, Nairobi, Kenya, Canada
 

Alkalinity control makes sludge in soft form, which can be easily blown down from bottom side of BOILER.

Equivalent Product Other valuable peer company product :

Nalco 22372 RXSOL-50-5020-025 Boiler Water Treatment Auto
Nalco3DT- 465 RXSOL-40-4091-025   Scale and Corrosion Inhibitor for Cooling Water
Nalco ST 40 Rxsol-40-4009-025 MICRO BIOCIDE Cooling Water 
Nalco 77224 RXSOL-50-5002-025 Alkalinity Control 
Nalcool 2000 RXSOL-40-2000-025 RXSOL 2000 Corrosion Inhibitor 
Nalco ST40 RXSOL-40-4009-025 MICRO BIOCIDE Cooling Water
Nalco 404  RXSOL-50-5021-025  Hardness Control Liquid
Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates



One Shot Universal Liquitreat 100

Product Code ::RXSOL-50-5001-025
Product Short Description: A one-step and one SHOT treatment to control the formation of rust and scale in boilers. Contains alkaline compounds, scale and corrosion inhibitors, oxygen scavengers and sludge conditioners
Remarks:

Basic Boiler System Schematic

Below is a summary of problems associated with the common impurities in water and solutions to each problem.

List Of Problems Caused By Impurities In Water

Impurity (Chemical Formula)

Problems

Common Chemical Treatment Methods

Alkalinity (HCO3-, CO32- and CaCO3)

Carryover of feedwater into steam, produce CO2 in steam leading to formation of carbonic acid (acid attack)

Neutralizing amines, filming amines, combination of both, and lime-soda.

Hardness (calcium and magnesium salts, CaCO3)

Primary source of scale in heat exchange equipment

Lime softening, phosphate, chelates and polymers

Iron (Fe3+ and Fe2+)

Causes boiler and water line deposits

Phosphate, chelates and polymers

Oxygen (O2)

Corrosion of water lines, boiler, return lines, heat exchanger equipments, etc. (oxygen attack)

Oxygen scavengers, filming amines and deaeration

pH

Corrosion occurs when pH drops below 8.5

pH can be lowered by addition of acids and increased by addition of alkalies

Hydrogen Sulfide (H2S)

Corrosion

Chlorination

Silica (SiO2)

Scale in boilers and cooling water systems

Lime softening

Other Equivalent Brand:

RXSOL BWT LIQUID PLUS, Care Treat 3 Boiler 2, Drew Ameroid, Arboiler WT, BWT 104P Nor chem, B.W.T. NEW FORMULA EQUAL TO DREW - AGK 100, DM-511, EAZY BWT-1, MAXTREAT-3222, ONE SHOT BWT, Liquitreat 25 Ltr, Maxgreen 3266, MAXTREAT 3333, AGK-100

Images: Alt

Keyword:

Chemical feed should be continuous. Chemical pumping rates can create problems especially for neat feed set ups. Using on/off feed systems such as a recycle timer can create problems. Chemical feed pumps should be sized or product strengths should be adjusted to allow continuous feed.

Steam and carbon dioxide leave continuously, so setting up a neutralizing amine pump to feed intermittently can lead to wide variations in condensate pH control. If sampling is done from a condensate receiver, the tank volume may buffer the variations and the changes may not be noticed, but corrosion could be occurring to areas of the piping that see the rapidly changing pH.


If polymeric dispersants, phosphonates, phosphate, or chelants are fed intermittently into the feedwater using a recycle timer, and the amines are not fed continuously, a cycle of iron slugs returning in the condensate can be followed by slugs of high dispersancy cleaning of the iron from the deaerator and dragging it into the boiler.

Load changes can affect chemical concentrations when the chemical feed is base fed. Example: Steam production of one million lbs./day; 4% blowdown; 20% active boiler polymer product fed at 5 pounds per day. The calculated daily average polymer concentration would be 24 ppm. Assume peak plant production load is 60,000 lbs./hr., but during the overnight hours the load is only 5,000 lbs./hr. If the dispersant is being fed continuously over the 24 hours, during the 8- hour low load period, the boiler polymer concentration would have increased to over 200 ppm. Upon high fire when production resumes, carryover is very possible because of over concentrating the polymeric dispersant.

Chemical feed needs to be paced to steam production, especially where significant load changes occur.

Carbon dioxide can concentrate in steam and condensate making neutralizing amine treatment impractical. Carbon dioxide levels can be relatively low in steam exiting a boiler at only a few ppm, but if there are areas where it becomes “trapped” and can accumulate, concentrations can reach extremely high levels into the hundreds or even thousands of ppm.

CO2 is a non-condensable gas. It has a distribution ratio in the steam piping and condenses at points throughout the system. At the boiling point, the solubility of the gas in water is extremely low. The solubility of the CO2 is actually lower in the condensate than it is in the steam. For the CO2 to escape from the steam into the water it will accumulate in the steam space just above the water level until the partial pressure becomes high enough for the CO2 in the incoming steam to be able to exit into the condensate. This creates a steady state condition of CO2 coming in and exiting, but an area of severe localized corrosion occurs where the carbon dioxide concentration is high.

The highest CO2 concentration normally occurs just above the condensate water level. If there is an area where condensation is occurring and running down pipes or the sides of vessels, the CO2 concentration will be very high and the pH will be about 5.3 – 5.5 in that location creating high corrosion rates.


The solubility of CO2 increases dramatically as the condensate temperature falls below 212 °F. When there is an accumulation of CO2 in an area and the condensate temperature is relatively low, the amount of carbon dioxide going into solution will be extremely high. Where low-pressure steam is used that contains CO2 and the heat exchange process has relatively close temperature differentials between the steam and the condensate, there is potential for high uptake of the CO2 into the condensate and localized low pH.

Neutralizing amines are selected in an effort to condense in the right concentrations to carbon dioxide condensation levels throughout the steam system. Neutralizing amines cannot control corrosion where this localized accumulation of carbon dioxide occurs since the high CO2 overwhelms the demand for the amine. Even point source addition of amine may not be able to satisfy the demand.

Where the concentrating effect of CO2 occurs, methods of reducing the problem include eliminating or minimizing CO2 in the steam, venting off the CO2 in the localized area, eliminating condensate in the area, applying a filming amine or metal passivator, or using higher temperature steam and increasing condensate temperature to reduce the CO2 content in the condensate.

packaing_size:

Boiler water and feed water treatment speacialized chemical products One Shot Universal Liquitreat  Exporter, manufacturer, supplier in Mumbai, Gandhidham - Kandla, Mundra, Sikka, Surat, Kolkata - Haldia, Buz Buj, Paradip, Visakhapatnam - Gangavaram, Fujairah, Dubai, Sharjah, Abu Dhabi, Ruwi Barka Muscat Sohar, Oman, Sudan, Yemen, Nairobi Kenya

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates



Condensnol Amine Evaporator Treatment

Product Code ::RXSOL-50-5005-020
Product Short Description: LIQUID CONDENSATE CORROSION CONTROL FOR BOILER SYSTEMS
Remarks:

RXSOL-50-5005-CC alkaline and the vapors are irritating to eyes and lungs. Avoid contact with eyes and skin. Do not take internally. Observe safety regulations wear Goggles, PVC gloves and Apron when handling Provide ample ventilation Avoid contact with skin in case of contacts wash with cupious amount of water immediately. If eyes are splashed give immediate and prolonged irrigation with clean running water and obtain medical attention.

Not for internal use :-
If swallowed do not induce vomiting give plenty of water or milk and call a doctor immediately.

Packing. GENERAL REMARKS:-Do not store  RXSOL-50-5005-CA  near a heating equipment.

Other Equivalent Brand:

GREEN CC, RXSOL 9-150 / SLCC-A, Care Treat-4, MARICHEM C.C.I.TM, Maxtreat 3330, DM-530, Condensate Control 20 Ltr,Condensate Control 20 Ltr

Images: Alt

Keyword:

We are also keeping ready stock of full range of marine chemicals, Some of valuable marine products are as follows :::

ALKAATUFF Ship Hold Cleaner
CHLORINATED ISOCYANURATE TABLETS
CHLORINE Liquid
Oil Spill Dispersant
DESCALING CHEMICAL
ELECTROSOLV E
Enviro Degreaser
PERMANGANATE TABLETS
NITRITE BORAX CORROSION INHIBITOR LIQUID

packaing_size:

Condensnol Amine Evaporator Treatment manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Condensnol Amine Evaporator Treatment at a competitive price from us. We have ready stock of Condensnol Amine Evaporator Treatment in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates
Get MSDS
Get Technical Bulletin
Connect On Whats App



Sodium Tri Poly Phosphate STPP RXSOL

Product Code ::RXSOL-19-1523-025
Product Short Description: STPP RXSOL
Remarks:
Other Equivalent Brand:

STPP

Images: Alt

Keyword:

packaing_size:

STPP - Sodium Tri Poly Phosphate STPP RXSOL supplier exporter importer in Mumbai, Kandla, Kolkata, Chennai, Surat, Ennore, Vizag Visakhapatnam, Fujairah, Muscat, Dubai, Sharjah, Abudhabi, UAE GULF, Ruwi Barka Sohar Oman, Nairobi Kenya

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates
Get MSDS
Get Technical Bulletin
Connect On Whats App



EDTA-Ethylene Diamine TetraAcetic Acid

Product Code ::RXSOL-19-1519-025
Product Short Description: Disodium EDTA is a derivative of Ethylenediamine Tetraacetic Acid.
Remarks:

Uses / Application of Disodium EDTA
Disodium EDTA is a Sequestering Agent, which is used in various Industries such as Pharmaceutical, Photography, Textile, Boiler Turbine scale removal, Agriculture. It is used for removing unwanted inorganic impurities present in the system, which helps in getting superior performance & cost saving.

Other Equivalent Brand:

Ethylenediaminetetraacetic Acid Disodium Salt, N,N,1-2-ethanediylbis N-carboxymethyl glycine Edetic Acid Disodium Salt, Disodium Edetate, Metaclaw, Trilon B, Versene 220, Dissolvine, Titriplex, Dreplex OX, EDTA 25 Kg

Images: Alt

Keyword:


packaing_size:

EDTA - Ethylene Diamine TetraAcetic Acid Exporter and supplier in Fujairah, Dubai, Ajman, Abudhabi, Sharjah, RUWI BArka, Muscat Sohar Oman, Sudan, Yemen, Nairobi Kenya, Mumbai, Nashik Pune Maharastra, Surat Gandhidham, Gujrat, Kolkata, Haldia, Paradip, Visakhapatnam, Andhrapradesh, Chennai Tamilnadu

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates
Get MSDS
Get Technical Bulletin
Connect On Whats App



Diethyl Amino Ethanol

Product Code ::RXSOL-19-1121-025
Product Short Description: 2-DIETHYLAMINOETHANOL is an organic compound with amine and alcohol substituents.
Remarks:

Never use DEAE in an open ventilation system, its oily residue can deposit on all available surfaces and results oil residue deposition. DEAE produces an oily residue which can soften varnishes.

Other Equivalent Brand:

Diethylaminoethanol, DEAE, USED as O2 scavenger in boiler water, Not For Export

Images: Alt

Keyword:

packaing_size:

DIETHYL AMINO ETHANOL manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of DIETHYL AMINO ETHANOL at a competitive price from us. We have ready stock of DIETHYL AMINO ETHANOL in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates
Get MSDS
Get Technical Bulletin
Connect On Whats App



Oxygen Controller Scavenger

Product Code ::RXSOL-50-5023-025
Product Short Description: This is most common oxygen scavengers used to effectively remove dissolved OXYGEN from your feedwater.
Remarks:
Other Equivalent Brand:
Images: Alt

Keyword:

packaing_size:

Oxygen Controller Scavenger manufacturer, exporter supplier in Mumbai, Surat, Goa, MAnglore, Chennai, Vizag Visakhapatnam, Kolkata, Haldia, Ajman, Fujairah, Dubai, Abudhabi, Sharjah, UAE, Muscat Oman

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates
Get MSDS
Get Technical Bulletin
Connect On Whats App



A. Guide Line Manual for Boiler

Product Code ::RXSOL-50-5009-100
Product Short Description: A. Guide Line Manual for Boiler
Remarks:
Other Equivalent Brand:
Images: Alt

Keyword:

packaing_size:

A. Guide Line Manual for Boiler manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of A. Guide Line Manual for Boiler at a competitive price from us. We have ready stock of A. Guide Line Manual for Boiler in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates
Get MSDS
Get Technical Bulletin
Connect On Whats App



Oxygen Remover Scavanger Plus

Product Code ::RXSOL-50-5022-025
Product Short Description: Oxygen Scavenger Plus is a catalysed liquid solution of Hydrazine and diethylhydroxylamine (DEHA). Its volatile properties ensure distribution throughout the boiler and condensate system, and hence protects against oxygen corrosion in all parts of t
Remarks:

The establishment of protective metal oxide lay-ers through the use of reducing agents (such as hydrazine, hydroquinone, and other oxygen scavengers) is known as metal passivation or metal conditioning. Although "metal passivation" refers to the direct reaction of the compound with the metal oxide and "metal conditioning" more broadly refers to the promotion of a protective surface, the two terms are frequently used interchangeably.

The reaction of hydrazine and hydroquinone, which leads to the passivation of iron-based metals, proceeds according to the following reactions:

N2H4 +  6Fe2O3 ® 4Fe3O4 +  2H2O  +  N2
hydrazine    hematite    magnetite    water    nitrogen

 

C6H4(OH)2 + 3Fe2O3 ® 2Fe3O4 + C6H4O2 + H2O
hydroquinone   hematite   magnetite   benzoquinone   water

 

Similar reactions occur with copper-based metals:

N2H4 + 4CuO ® 2Cu2O + 2H2O + N2
hydrazine   cupric oxide   cuprous oxide   water   nitrogen

 

C6H6O2 + 2CuO ® Cu2O + C6H4O2 + H2O
hydroquinone   cupric oxide   cuprous oxide   benzoquinone   water

 

Magnetite and cuprous oxide form protective films on the metal surface. Because these oxides are formed under reducing conditions, removal of the dissolved oxygen from boiler feedwater and condensate promotes their formation. The effective application of oxygen scavengers indirectly leads to passivated metal surfaces and less metal oxide transport to the boiler whether or not the scavenger reacts directly with the metal surface.

A significant reduction in feedwater oxygen and metal oxides can occur with proper application of oxygen scavengers.

Other Equivalent Brand:

9-035 PLUS, Oxygen Scavenger 9-035, Oxytreat-H, INDION 2587, Hydrazine Oxygen Scanvanger, Maxtreat-3220, AHT 101 Hydrazine

Images: Alt

Keyword:

Where Hydrazine Test Kit used ?

HYDRAZINE TEST KIT is used for the determination of Hydrazine content in the Boiler’s Water. The test must be performed when in the vessel’s Boiler Water Treatment used hydrazine ingredient to control rust and corrosion RXSOL-50-5022-025 / RXSOL-50-5007-025 / RXSOL-19-1541-025. This is an activated hydrazine solution (Hydrazine with a catalyst for faster reaction with Dissolved Oxygen,) and applied for marine and industrial Boilers in low, medium and high pressures. 

packaing_size:

Oxygen Remover Scavanger Plus manufacturer, exporter and supplier in Mumbai, Gandhidham Kandla, Chennai Ennore, Kolkata Haldia, Vizag Visakhapatnam, Paradip, Haldia, Fujairah, Dubai, Ajman, Sharjah, ABudhabi, Muscat Oman, Canada BC

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates
Get MSDS
Get Technical Bulletin
Connect On Whats App



Morpholine

Product Code ::RXSOL-19-1382-025
Product Short Description: 99%-99.5% pure material can be use as Coating Auxiliary Agents, Plastic Auxiliary Agents, Rubber Auxiliary Agents, Surfactants, Textile Auxiliary Agents, Water Treatment Chemicals
Remarks:

Our regular customer of morpholine getting advantage of our pure imported morpholine as per there customized packing and requirements.

Other Equivalent Brand:

pH Booster, Fruit Coating Emulsifier

Images: Alt

Keyword:

Morpholine chemicals formula is O(CH2CH2)2NH and Molecular formula is C4H9NO
 

RXSOL Brand is popular as a water treatment chemicals Company in India, UAE, Oman, Nairobi, and Sudan. Some of our water treatment chemicals RAW MATERIALS product list.

1 Cyclohexylamine CHA 108-91-8
2 Morpholine MORPH 110-91-8
3 3-Methoxypropylamine MOPA 5332-73-0
4 N,N-Diethylhydroxylamine   DEHA 3710-84-7
5 Hydrazine Hydrate HH 10217-52-4
6 Carbonyl Dihydrazine CBDH 497-18-7
7 Acetone Oxime DMKO 127-06-0
8 EDTA-2Na EDTA-2Na 6381-92-6
9 EDTA-4Na EDTA-4Na 10378-23-1
10 2,2-Dibromo-2-Cyanoacetamide DBNPA 10222-01-2
11 Benzalkonium Chloride BAC 63449-41-2
12 Polyhexamethylene Guanidine PHMG 57028-96-3
13 Sodium Bromide NaBr 7647-15-6
14 Polyacrylamide PAM 9003-5-8
15 Sodium Molybdate SUMO 7631-95-0
16 Sodium Tripolyphosphate STPP 7758-29-4
       

Water Treatment Chemicals supplier in your city nearby you in your COUNTRY INDIA, OMAN, UAE, NAIROBI

packaing_size:

Morpholine Supplier, Distributor and Exporter Kandla, Mumbai, Chennai, Visakhapatnam, Kolkata, Fujairah, Dubai, Sharjah, Abu Dhabi, Ajman, Muscat Ruwi Barka Sohar OMan, Nairobi, Kenya, Sudan, Yemen

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates