Your shopping cart is empty.

Boiler Chemicals-42




Condenser Coil Cleaner

Product Code ::RXSOL-42-5015-005
Product Short Description: It is a specially engineered condenser coil cleaner and brightener. this product is recommended for use in hotels, commercial complexes, hospitals, shipyards and any air-conditioning workshops or establishments that services air conditioning systems.
Remarks:


This product is avilable with all our associated ship chandlers of INDIA and Middle East by product code no RXSOL-16-1028-025.

we are manufactrer of RXSOL-16-1028-025 , and supplier in kakinada, Visakhapatnam, Vizag, Mumbai, Goa, Surat, Gandhidham, Kandla, Mundra, Chennai, Ennore, Kolkata, Haldia, Pirpav, Fujairah, Dubai, Sharjah, Abu Dhabi and Gulf.

RXSOL brand Aluminium Cleaner exporter for TURKEY, Australia.

Other Equivalent Brand:

Condensor Coil Cleaner Red 5 ltrs

Images: Alt

Keyword:

Powerful Solid Aluminium Cleaner

Wipe on. Wash off Aluminium Cleaner

The ease and speed of RXSOL advanced technology Aluminium Cleaner for Solid Aluminium fixtures and fittings etc.. makes it the cleaning product of choice for every Householder, Antique Restorer, Cleaning Company and is the Bar Keepers friend. Removes; Heat Discolouration caused by over heating, Mildew, Burn marks Flame marks,Tarnish, Mould, Mildew, Rust and Stains
RXSOL Aluminium Cleaner sanitizes killing 99.9% of germs, is safe to touch, smells fresh, usable without gloves without the need for tedious scrubbing, and is Safe on the environment.
One Tub of RXSOL Aluminium Cleaner replaces a dozen of other supermarket cleaning products saving money and time, Making valuable room in your cleaning cupboard shelves.

Aluminium Cleaner cleaning solution
Help is at hand, though, in the form of RXSOL  a revolutionary new cleaning system that is taking the world by storm Compared to many other types of Aluminium Cleaner or metal cleaners available, RXSOL offers a whole array of features and benefits. It has received an independent review rating as being the most convenient, effective, easy-to-use, non-odour, cost-effective and non-toxic cleaning detergent on the market today.
Most importantly, RXSOL is safe to use and highly effective. This product is 11 times more powerful than caustic soda yet it is harmless and surprisingly contains no phosphorous. It requires no gloves, is safe to touch, there are no fumes given off, no odour and no smell. 
RXSOL is also many times more powerful than other well-known Aluminium metal cleaners. 
The wipe-on, wipe-off formula means that RXSOL is also an extremely easy to use cleaner and will save you time. 
Its fast, concentrated solution means that just a small amount will quickly tackle a large area.
As long as your Aluminium isn't lacquered, even heavy tarnish will be effortlessly removed from its surface. And as it is non-abrasive, RXSOL is equally suitable for use on your most delicate or treasured copper items such as antiques. 
The protection offered by RXSOL will last for a long time as it contains an anti-tarnish corrosion inhibitor which will keep your Aluminium cleaner for longer. 
Value for money is ensured by the simple fact that RXSOL is a multi-purpose all-in-one product. Ideal for restoring shine to Aluminium it will also remove years of accumulated dirt, tarnish and oxidisation from many other metals including stainless steel, brass, silver, aluminium, tiles and ceramics. 
Instead of having to buy a separate cleaner for your Aluminium pans, your silver jewellery and other household metal items, RXSOL will do it all! And, because it is available in a choice of four different sizes ranging from 500g right up to 10kg, you only need to buy the amount of cleaner you actually need. 
So, if you want to restore the lustrous shine and polish to your Aluminium fixtures and fittings with minimum effort and long-lasting results.  RXSOL is the cleaner for you!

packaing_size:

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates



Zinc Chloride Solution

Product Code ::RXSOL-42-6141-051
Product Short Description: Zinc chloride solution is a colorless liquid. It is mildly corrosive to metals. It causes burns to eyes skin and mucous membranes.
Remarks:
Other Equivalent Brand:
Images: Alt

Keyword:

packaing_size:

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates



Scale Remover 1507

Product Code ::RXSOL-42-1008-0025
Product Short Description: Scale dissolver. Specifically formulated to remove rust and water scale build up from boiler evaporators, heat exchangers, cooling systems, pipeline collection system etc. Highly effective on heating. Safe and easy handling and storage.
Remarks:

-   Prevent run off water from entering drains if possible

Formation of Calcium Sulfate is main cause for SCALE formation :::

The principal problem potential posed by sulfate ions in water is the possibility of calcium sulfate scale formation.  Precipitation of calcium sulfate can occur when high concentrations of both calcium and sulfate exist simultaneously.  There are three primary areas of water treatment in which calcium sulfate precipitation may occur boilers, cooling systems, and ion exchangers operating in the hydrogen or acid mode.

In boilers, calcium sulfate scale formation has been reduced to a minimum by modern treatment practices.  The low hardness levels largely preclude calcium sulfate boiler scale.    By contrast, cooling systems are subject to calcium sulfate scale deposition because the makeup is usually not treated for hardness removal.  Cooling water is usually treated with sulfuric acid for pH control, and the makeup is cycled, i.e. concentrated.  Calcium sulfate scale deposition can  result unless the cycles of concentration are properly controlled in conjunction with the proper use of scale control chemicals.  Cation ion exchangers regenerated with sulfuric acid also can pose a major calcium sulfate problem. Calcium sulfate precipitation can be avoided by controlling the acid concentration and the flow rate through the exchanger.  

Sulfate content can be calculated in Laboratory by using this method ::: http://rxmarine.com/SULFATE-TEST-KIT

Other Equivalent Brand:

INDION 1507 Colour Indicator Scale Remover Liquid

Images: Alt

Keyword:

The scale remover contains colour pH indicator with scale dissolving Dry Acid powder which is effectively  dissolves Scale and presence of  corrosion inhibitor protect metal steel parts, cast iron and copper alloys during descaling process And  wetting agent component of scale remover enhance cleaning action which is resulting quick descaling cleaning operation.

packaing_size:

Scale remover manufacturer and supplier in Karwar, Visakhapatnam, chennai, Ennore, Kolkata, Haldia, Mumbai, Kandla, Surat, Fujairah, Sharjah, Dubai, Abudhabi, UAE Muscat Oman

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates
Get MSDS
Get Technical Bulletin
Connect On Whats App



AMERZAMINE

Product Code ::RXSOL-14-5005-554
Product Short Description: 100 percent water soluble and 100 percent Volatile corrosion inhibitor for Low Medium High Pressure Boiler Water System.
Remarks:

Basic Boiler System Schematic

Below is a summary of problems associated with the common impurities in water and solutions to each problem.

List Of Problems Caused By Impurities In Water

Impurity (Chemical Formula)

Problems

Common Chemical Treatment Methods

Alkalinity (HCO3-, CO32- and CaCO3)

Carryover of feedwater into steam, produce COin steam leading to formation of carbonic acid (acid attack)

Neutralizing amines, filming amines, combination of both, and lime-soda.

Hardness (calcium and magnesium salts, CaCO3)

Primary source of scale in heat exchange equipment

Lime softening, phosphate, chelates and polymers

Iron (Fe3+ and Fe2+)

Causes boiler and water line deposits

Phosphate, chelates and polymers

Oxygen (O2)

Corrosion of water lines, boiler, return lines, heat exchanger equipments, etc. (oxygen attack)

Oxygen scavengers, filming amines and deaeration

pH

Corrosion occurs when pH drops below 8.5

pH can be lowered by addition of acids and increased by addition of alkalies

Hydrogen Sulfide (H2S)

Corrosion

Chlorination

Silica (SiO2)

Scale in boilers and cooling water systems

Lime softening

Other Equivalent Brand:

Amerzine 25 Ltr

Images: Alt

Keyword:

packaing_size:

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates
Get MSDS
Get Technical Bulletin
Connect On Whats App



CHEMZOL 9200

Product Code ::RXSOL-42-1524-050
Product Short Description: Extremely suitable oxygen scavenger for low and medium pressure boilers.
Remarks:

The most common oxygen scavengers in oilfield production are sodium bisulfite (SBS) and ammonium bisulfite (ABS). Ammonium bisulfite is more water soluble than sodium bisulfite and typically react with oxygen faster. However, ammonium in the ammonium bisulfite can promote bacteria growth.

Being a salt of a weak acid and a strong base, sodium bisulfite forms a significantly basic aqueous solution whereas ammonium bisulfite is only slightly basic at around pH 8. As a rule of thumb, 60ppm of 65wt% ammonium bisulfite is required to reduce the oxygen concentration in water from 9ppm to 50ppb.

The reaction of bisulfite with oxygen is typically faster at higher temperatures and can be facilitated by transition metal ion catalysts, e.g. Cobalt.

The most common applications of oxygen scavenger in oil and gas production are for seawater injection facilities, hydro-testing, and acid stimulation

It is used to arrest oxygen in sea water

It removes Entrapped Oxygen and thus reduces Corrosion

In Oil Drilling Chemicals

Other Equivalent Brand:

Chemsol 9200

Images: Alt

Keyword:

Oxygen Scavenger Boiler Oxy Control effective OXYGEN SCAVENGER for drilling fluid.

An oxygen scavenger is a chemical substance that is used to reduce or completely remove oxygen in fluids and enclosed spaces to prevent oxygen-induced corrosion

Oxygen Scavenger Boiler Oxy Control works as an oxygen absorber. It is used as a corrosion inhibitor in oil and gas production installations, packaging, production separation and seawater injection systems. Oxygen scavengers increase the shelf life or service life of the components under protection

Oxygen scavengers are categorized as organic or inorganic. They are applied in various ways, depending on

packaing_size:

Oxygen Scavenger Boiler Oxy Control supplier and exporter from Mumbai, Chennai, Kolkata, Visakhapatanm, Gandhidham, Fujairah, Sharjah, Dubai, Abudhabi, Gulf Middle East, Muscat Barka Sohar Oman, Nairobi Kenya Africa, Canada

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates
Get MSDS
Get Technical Bulletin
Connect On Whats App



Corrosion Scale Inhibitor Boiler Treatment

Product Code ::RXSOL-42-4029-025
Product Short Description: Corrosion and Scale Inhibitor with Phosphates and Polyphosphates.
Remarks:

Frequently Asked Questions about Boiler treatment

Q1. What is a corrosion scale inhibitor and why is it important for boilers?

Answer:

A corrosion scale inhibitor is a chemical solution designed to prevent rust, corrosion, and scale formation inside boiler systems. It protects metal surfaces from degradation and ensures smooth heat transfer, ultimately extending the lifespan of the boiler and reducing energy costs and maintenance downtime.

Q2 How do I choose the right scale inhibitor for my boiler?

Answer:

Choosing the right inhibitor depends on:

  • Boiler pressure and temperature

  • Feedwater quality (e.g., hardness, pH, oxygen content)

  • Type of scaling or corrosion (e.g., calcium carbonate vs. oxygen pitting)

Look for inhibitors that are multi-functional, offering both scale and corrosion protection, and ensure they’re compatible with your boiler material (carbon steel, copper alloys, etc.).

Q3 How often should I dose my boiler with a corrosion scale inhibitor?

Answer:

The frequency of dosing depends on your boiler’s operating conditions, feedwater quality, and the type of inhibitor used. Typically, dosing is done continuously through a dosing pump or daily during boiler operation. Regular water testing and monitoring (pH, conductivity, hardness) is essential to maintain the correct inhibitor levels and ensure optimal protection against corrosion and scale.

Other Equivalent Brand:

Corrosion Inhibitor Phosphate base for Boiler Systems, NALCO 22310, NexGuard 22310 Polymer Dispersant for Steam Boilers, FLOGARD POT6102, NALCO 77225

Images: Alt

Keyword:

Corrosion and Scale Inhibitor (Bi-functional) Cooling water System, Phosphate based product.

Why Choose RXSOL Corrosion Scale Inhibitor for Boiler?

Choosing RXSOL Corrosion Scale Inhibitor for Boiler means opting for reliable scale prevention that keeps your boiler systems free from scale build-up, ensuring they maintain efficiency and performance. Its comprehensive corrosion protection, featuring an iron/tannate film and oxygen removal, provides robust protection for your entire system. The low toxicity formulation ensures safe handling while delivering effective results.

Industry professionals prefer RXSOL Corrosion Scale Inhibitor for its proven effectiveness in protecting critical infrastructure, making it a trusted choice in the field.

Features

Liquid Product: Easy application for convenience.

Benefits

Enhanced Protection: Safeguards feed tank, feed lines, and boiler metal from corrosion and scale. Maintains Water Quality: Does not add to boiler Total Dissolved Solids (TDS).

packaing_size:

Corrosion Scale Inhibitor Boiler Treatment manufacturer and supplier in Mumbai, Turbhe Pawana MIDC, Gandhidham, Visakhapatnam, Chennai Ennore, Kolkata, Haldia, Ajman, Fujairah, Dubai, Sharjah, Dubai, Muscat, Oman, Sohar, Barka, Canada, SUDAN, Yemen

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates
Get MSDS
Get Technical Bulletin
Connect On Whats App



CHEMZOL 941

Product Code ::RXSOL-42-4029-050
Product Short Description: Corrosion and Scale Inhibitor with Phosphates and Polyphosphates.
Remarks:

Frequently Asked Questions about Boiler treatment

Q1. What is a corrosion scale inhibitor and why is it important for boilers?

Answer:

A corrosion scale inhibitor is a chemical solution designed to prevent rust, corrosion, and scale formation inside boiler systems. It protects metal surfaces from degradation and ensures smooth heat transfer, ultimately extending the lifespan of the boiler and reducing energy costs and maintenance downtime.

Q2 How do I choose the right scale inhibitor for my boiler?

Answer:

Choosing the right inhibitor depends on:

  • Boiler pressure and temperature

  • Feedwater quality (e.g., hardness, pH, oxygen content)

  • Type of scaling or corrosion (e.g., calcium carbonate vs. oxygen pitting)

Look for inhibitors that are multi-functional, offering both scale and corrosion protection, and ensure they’re compatible with your boiler material (carbon steel, copper alloys, etc.).

Q3 How often should I dose my boiler with a corrosion scale inhibitor?

Answer:

The frequency of dosing depends on your boiler’s operating conditions, feedwater quality, and the type of inhibitor used. Typically, dosing is done continuously through a dosing pump or daily during boiler operation. Regular water testing and monitoring (pH, conductivity, hardness) is essential to maintain the correct inhibitor levels and ensure optimal protection against corrosion and scale.

Other Equivalent Brand:

Chemsol 941

Images: Alt

Keyword:

Corrosion and Scale Inhibitor (Bi-functional) Cooling water System, Phosphate based product.

packaing_size:

Corrosion Scale Inhibitor Boiler Treatment manufacturer and supplier in Mumbai, Turbhe Pawana MIDC, Gandhidham, Visakhapatnam, Chennai Ennore, Kolkata, Haldia, Ajman, Fujairah, Dubai, Sharjah, Dubai, Muscat, Oman, Sohar, Barka, Canada, SUDAN, Yemen

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates
Get MSDS
Get Technical Bulletin
Connect On Whats App



Alkaline Corrosion Inhibitor for Boiler

Product Code ::RXSOL-42-1308-025
Product Short Description: Caustic based alkaline corrosion inhibitor for Boiler treatment
Remarks:
Other Equivalent Brand:

Aquatreat 1275

Images: Alt

Keyword:

packaing_size:

Alkaline Corrosion Inhibitor for Boiler manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Oman, Kenya Africa. Get the best quality of Alkaline Corrosion Inhibitor for Boiler at a competitive price from us. We have ready stock of Alkaline Corrosion Inhibitor for Boiler in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates
Get MSDS
Get Technical Bulletin
Connect On Whats App



OxyShield Plus Boiler Oxygen Scavenger

Product Code ::RXSOL-42-5029-200
Product Short Description: Scavenges oxygen and passivates iron and copper surfaces, rendering them more resistant to corrosion
Remarks:

#OxygenScavengerforBoiler

#OxygenScavengermanufacturer

#OxygenScavengersupplier

#AminebasedOxygenScavenger

Other Equivalent Brand:

Oxygen Scavenger Plus, Oxygen Scavenger for High Pressure Boiler, CB22 / AT-2344, DEHA Based Oxygen Scavenger, Amine Based Oxygen Scavenger 210 Ltr

Images: Alt

Keyword:

packaing_size:

Oxygen Scavenger for Boiler Water exporter and supplier in India UAE Middle East Oman Kenya Africa. Oxygen Scavenger for Boiler Water supplier in Mumbai, Kandla Surat Gujrat, Kolkata, West Bengal, Chennai Tamilnadu, Visakhapatnam, Andhra Pradesh, Dubai, Fujairah, Abudhabi, Sharjah, Ajman, Muscat Barka Sohar, Nairobi Kenya Sudan, Yemen Tanzania Africa

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates
Get MSDS
Get Technical Bulletin
Connect On Whats App



Multi Functional Boiler Treatment

Product Code ::RXSOL-42-5001-025
Product Short Description: Highly effective multi-functional liquid reagent for the treatment of steam production systems and heating systems operating on softened water.
Remarks:

RXSOL-42-5001-025 Boiler Water treatment specialized is a well - balanced blend for boiler water treatment products, Resulting Multi Functional Boiler Treatment including scale and corrosion control by one shot operation. A one-step treatment to control the formation of rust and scale in low pressure and auxillary boilers with working pressure up to 20 bars.

The stability of the added polymers are very useful for water treatment processes. Such polymers with low molecular weights cannot only inhibit calcium, magnesium, and silica scale in cooling towers and boilers, but also help corrosion control by dispersing iron oxide. 


Basic Boiler System Schematic

Below is a summary of problems associated with the common impurities in water and solutions to each problem.

List Of Problems Caused By Impurities In Water

Impurity (Chemical Formula)

Problems

Common Chemical Treatment Methods

Alkalinity (HCO3-, CO32- and CaCO3)

Carryover of feedwater into steam, produce COin steam leading to formation of carbonic acid (acid attack)

Neutralizing amines, filming amines, combination of both, and lime-soda.

Hardness (calcium and magnesium salts, CaCO3)

Primary source of scale in heat exchange equipment

Lime softening, phosphate, chelates and polymers

Iron (Fe3+ and Fe2+)

Causes boiler and water line deposits

Phosphate, chelates and polymers

Oxygen (O2)

Corrosion of water lines, boiler, return lines, heat exchanger equipments, etc. (oxygen attack)

Oxygen scavengers, filming amines and deaeration

pH

Corrosion occurs when pH drops below 8.5

pH can be lowered by addition of acids and increased by addition of alkalies

Hydrogen Sulfide (H2S)

Corrosion

Chlorination

Silica (SiO2)

Scale in boilers and cooling water systems

Lime softening

Other Equivalent Brand:

Care Treat 3 Boiler 2 Arboiler WT, BWT 104P Nor chem, Amertrol AT1240, Drew Ameroid 25 Ltr

Images: Alt

Keyword:

Chemical feed should be continuous. Chemical pumping rates can create problems especially for neat feed set ups. Using on/off feed systems such as a recycle timer can create problems. Chemical feed pumps should be sized or product strengths should be adjusted to allow continuous feed.

Steam and carbon dioxide leave continuously, so setting up a neutralizing amine pump to feed intermittently can lead to wide variations in condensate pH control. If sampling is done from a condensate receiver, the tank volume may buffer the variations and the changes may not be noticed, but corrosion could be occurring to areas of the piping that see the rapidly changing pH.


If polymeric dispersants, phosphonates, phosphate, or chelants are fed intermittently into the feedwater using a recycle timer, and the amines are not fed continuously, a cycle of iron slugs returning in the condensate can be followed by slugs of high dispersancy cleaning of the iron from the deaerator and dragging it into the boiler.

Load changes can affect chemical concentrations when the chemical feed is base fed. Example: Steam production of one million lbs./day; 4% blowdown; 20% active boiler polymer product fed at 5 pounds per day. The calculated daily average polymer concentration would be 24 ppm. Assume peak plant production load is 60,000 lbs./hr., but during the overnight hours the load is only 5,000 lbs./hr. If the dispersant is being fed continuously over the 24 hours, during the 8- hour low load period, the boiler polymer concentration would have increased to over 200 ppm. Upon high fire when production resumes, carryover is very possible because of over concentrating the polymeric dispersant.

Chemical feed needs to be paced to steam production, especially where significant load changes occur.

Carbon dioxide can concentrate in steam and condensate making neutralizing amine treatment impractical. Carbon dioxide levels can be relatively low in steam exiting a boiler at only a few ppm, but if there are areas where it becomes “trapped” and can accumulate, concentrations can reach extremely high levels into the hundreds or even thousands of ppm.

CO2 is a non-condensable gas. It has a distribution ratio in the steam piping and condenses at points throughout the system. At the boiling point, the solubility of the gas in water is extremely low. The solubility of the CO2 is actually lower in the condensate than it is in the steam. For the CO2 to escape from the steam into the water it will accumulate in the steam space just above the water level until the partial pressure becomes high enough for the CO2 in the incoming steam to be able to exit into the condensate. This creates a steady state condition of CO2 coming in and exiting, but an area of severe localized corrosion occurs where the carbon dioxide concentration is high.

The highest CO2 concentration normally occurs just above the condensate water level. If there is an area where condensation is occurring and running down pipes or the sides of vessels, the CO2 concentration will be very high and the pH will be about 5.3 – 5.5 in that location creating high corrosion rates.


The solubility of CO2 increases dramatically as the condensate temperature falls below 212 °F. When there is an accumulation of CO2 in an area and the condensate temperature is relatively low, the amount of carbon dioxide going into solution will be extremely high. Where low-pressure steam is used that contains CO2 and the heat exchange process has relatively close temperature differentials between the steam and the condensate, there is potential for high uptake of the CO2 into the condensate and localized low pH.

Neutralizing amines are selected in an effort to condense in the right concentrations to carbon dioxide condensation levels throughout the steam system. Neutralizing amines cannot control corrosion where this localized accumulation of carbon dioxide occurs since the high CO2 overwhelms the demand for the amine. Even point source addition of amine may not be able to satisfy the demand.

Where the concentrating effect of CO2 occurs, methods of reducing the problem include eliminating or minimizing CO2 in the steam, venting off the CO2 in the localized area, eliminating condensate in the area, applying a filming amine or metal passivator, or using higher temperature steam and increasing condensate temperature to reduce the CO2 content in the condensate.

packaing_size:

Boiler water treatment speacialized chemical products One Shot Universal Liquitreat  Exporter, manufacturer, supplier in Mumbai, Gandhidham - Kandla, Mundra, Sikka, Surat, Kolkata - Haldia, Buz Buj, Paradip, Visakhapatnam - Gangavaram, Fujairah, Dubai, Sharjah, Abu Dhabi, Ruwi Barka Muscat Sohar, Oman, Sudan, Yemen, Nairobi Kenya

Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates